Laser Power & Energy Meters

LaserPoint offers advanced solutions for the precise measurement of power and energy in laser systems. Their range of thermal sensors covers applications from low-power lasers to high-power lasers up to 40 kW, without the need for water cooling. Notable products include the high-speed BLINK sensor, ideal for ultrafast lasers with repetition rates up to 1 MHz and femtosecond pulse durations, and the Pulse Controller, designed for pulse-to-pulse energy measurement in fast and ultrafast lasers. With over 30 years of experience, LaserPoint is a reliable tool for professionals across various industries.

Iberoptics is distributor of LaserPoint solutions, offering expert guidance and local support to help customers select the most suitable power and energy meters for their laser applications.

Laser Power & Energy Meters
10-BB-D12-LLaserPointThermal SensorsMax. Average Power: 10 WMax. Energy (with 100 ms pulse): 10 JAbsorber Spectral Range: 0.4 - 2 µmAperture: 12 mmResponse Time (0-90%): 3 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
10-BB-D25LaserPointThermal SensorsMax. Average Power: 10 WMax. Energy (with 100 ms pulse): 10 JAbsorber Spectral Range: 0.4 - 5.2 µmAperture: 25 mmResponse Time (0-90%): 3 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
10-UVA-D25LaserPointThermal SensorsMax. Average Power: 10 WMax. Energy (with 100 ms pulse): 10 JAbsorber Spectral Range: 0.25 - 0.4 µmAperture: 25 mmResponse Time (0-90%): 3 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
10-UVC-D25LaserPointThermal SensorsMax. Average Power: 10 WMax. Energy (with 100 ms pulse): 10 JAbsorber Spectral Range: 0.19 - 0.25 µmAperture: 25 mmResponse Time (0-90%): 3 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
20-BB-D40LaserPointThermal SensorsMax. Average Power: 20 WMax. Energy (with 100 ms pulse): 20 JAbsorber Spectral Range: 0.4 - 5.2 µmAperture: 40 mmResponse Time (0-90%): 3 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
20-UVA-D40LaserPointThermal SensorsMax. Average Power: 20 WMax. Energy (with 100 ms pulse): 20 JAbsorber Spectral Range: 0.25 - 0.4 µmAperture: 40 mmResponse Time (0-90%): 3 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
20-UVC-D40LaserPointThermal SensorsMax. Average Power: 20 WMax. Energy (with 100 ms pulse): 20 JAbsorber Spectral Range: 0.19 - 0.25 µmAperture: 40 mmResponse Time (0-90%): 3 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
A-02-D12-BBFLaserPointThermal SensorsMax. Average Power: 200 mWMax. Energy (with 100 ms pulse): 200 mJAbsorber Spectral Range: 0.19 - 25 µmAperture: 10 mmResponse Time (0-90%): 2 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
A-10-D12-DIFLaserPointThermal SensorsMax. Average Power: 10 WMax. Energy (with 100 ms pulse): 15 JAbsorber Spectral Range: 0.2 - 2.1 µmAperture: 12 mmResponse Time (0-90%): 1 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
A-10-D12-HPBLaserPointThermal SensorsMax. Average Power: 10 WMax. Energy (with 100 ms pulse): 15 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 12 mmResponse Time (0-90%): 0.8 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
A-10-D20-BBFLaserPointThermal SensorsMax. Average Power: 10 WMax. Energy (with 100 ms pulse): 15 JAbsorber Spectral Range: 0.19 - 25 µmAperture: 20 mmResponse Time (0-90%): 1 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
A-10-D20-HPBLaserPointThermal SensorsMax. Average Power: 10 WMax. Energy (with 100 ms pulse): 15 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 20 mmResponse Time (0-90%): 1 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
A-1200-D60-SHCLaserPointThermal SensorsMax. Average Power: 1200 WMax. Energy (with 100 ms pulse): 1200 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 60 mmResponse Time (0-90%): 6 secCooling: Forced Air with Fan (a)Cable length - connector: 5.0 m - DB15 5.0 m – USB (U option) 5.0 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
A-2-D12-BBFLaserPointThermal SensorsMax. Average Power: 2 WMax Energy Density (2): 5ms pulse width: 3.6 J/cm² 10µs pulse width: 0.2 J/cm² 10ns pulse width: 0.1 J/cm²Absorber Spectral Range: 0.19 - 11 µmAperture: 12 mmResponse Time (0-90%): < 1 secCooling: Conduction (a)Cable length - connector: 1.5 m - Bare wire—View family documentation
A-2-D12-HPBLaserPointThermal SensorsMax. Average Power: 2 WMax Energy Density (2): 5ms pulse width: 36 J/cm² 10µs pulse width: 1.2 J/cm² 10ns pulse width: 0.3 J/cm²Absorber Spectral Range: 0.19 - 11 µmAperture: 12 mmResponse Time (0-90%): < 1 secCooling: Conduction (a)Cable length - connector: 1.5 m - Bare wire—View family documentation
A-200-D25-HPBLaserPointThermal SensorsMax. Average Power: 200 WMax. Energy (with 100 ms pulse): 250 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 25 mmResponse Time (0-90%): 1.7 secCooling: Forced Air with Fan (a)Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
A-200-D25-SHCLaserPointThermal SensorsMax. Average Power: 200 WMax. Energy (with 100 ms pulse): 250 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 25 mmResponse Time (0-90%): 1.7 secCooling: Forced Air with Fan (a)Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
A-200-D40-HPBLaserPointThermal SensorsMax. Average Power: 200 WMax. Energy (with 100 ms pulse): 250 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 40 mmResponse Time (0-90%): 2 secCooling: Forced Air with Fan (a)Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
A-200-D40-SHCLaserPointThermal SensorsMax. Average Power: 200 WMax. Energy (with 100 ms pulse): 250 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 40 mmResponse Time (0-90%): 2 secCooling: Forced Air with Fan (a)—Power Calibration Uncertainty: ± 3%View family documentation
A-200-D60-HPBLaserPointThermal SensorsMax. Average Power: 200 WMax. Energy (with 100 ms pulse): 250 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 60 mmResponse Time (0-90%): 3 secCooling: Forced Air with Fan (a)—Power Calibration Uncertainty: ± 3%View family documentation
A-200-D60-SHCLaserPointThermal SensorsMax. Average Power: 200 WMax. Energy (with 100 ms pulse): 250 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 60 mmResponse Time (0-90%): 3 secCooling: Forced Air with Fan (a)—Power Calibration Uncertainty: ± 3%View family documentation
A-30-D12-SHC-LLaserPointThermal laser power and single-shot energy sensor20 mW–30 W continuous; up to 45 W for at most 2 minutes100 mJ–45 J; 45 J maximum with 100 ms pulse0.2–1.1 µm12 mm diameter15 s (0–90%)ConvectionDB15; USB/RS-232 versions are separately selected optionsPower calibration: ±3%; energy calibration: ±5%View family documentation
A-30-D18-DIFLaserPointThermal SensorsMax. Average Power: 30 WMax. Energy (with 100 ms pulse): 45 JAbsorber Spectral Range: 0.2 - 2.1 µmAperture: 18 mmResponse Time (0-90%): 1.5 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
A-30-D25-HPBLaserPointThermal SensorsMax. Average Power: 30 WMax. Energy (with 100 ms pulse): 45 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 25 mmResponse Time (0-90%): 1.5 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
A-300-D60-HPBLaserPointThermal SensorsMax. Average Power: 300 WMax. Energy (with 100 ms pulse): 400 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 60 mmResponse Time (0-90%): 3.5 secCooling: Forced Air with Fan (a)Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
A-40-D25-HPBLaserPointThermal SensorsMax. Average Power: 40 WMax. Energy (with 100 ms pulse): 60 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 25 mmResponse Time (0-90%): 1.5 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
A-40-D33-DIFLaserPointThermal SensorsMax. Average Power: 40 WMax. Energy (with 100 ms pulse): 60 JAbsorber Spectral Range: 0.2 - 2.1 µmAperture: 33 mmResponse Time (0-90%): 1.8 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
A-40-D40-HPBLaserPointThermal SensorsMax. Average Power: 40 WMax. Energy (with 100 ms pulse): 60 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 40 mmResponse Time (0-90%): 1.8 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
A-40/200-D25-HPBLaserPointThermal SensorsMax. Average Power: 40 WMax. Energy (with 100 ms pulse): 200 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 25 mmResponse Time (0-90%): 1.7 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
A-40/200-D40-HPBLaserPointThermal SensorsMax. Average Power: 40 WMax. Energy (with 100 ms pulse): 200 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 40 mmResponse Time (0-90%): 1.7 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
A-40/200-D60-HPBLaserPointThermal SensorsMax. Average Power: 40 WMax. Energy (with 100 ms pulse): 200 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 60 mmResponse Time (0-90%): 3 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
A-5-D12-BBFLaserPointThermal SensorsMax. Average Power: 5 WMax Energy Density (2): 5ms pulse width: 3.6 J/cm² 10µs pulse width: 0.2 J/cm² 10ns pulse width: 0.1 J/cm²Absorber Spectral Range: 0.19 - 11 µmAperture: 12 mmResponse Time (0-90%): < 1 secCooling: Conduction (a)Cable length - connector: 1.5 m - Bare Wire—View family documentation
A-600-D40-HPBLaserPointThermal SensorsMax. Average Power: 600 WMax. Energy (with 100 ms pulse): 800 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 40 mmResponse Time (0-90%): 5 secCooling: Forced Air with Fan (a)Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
A-600-D60-SHCLaserPointThermal SensorsMax. Average Power: 600 WMax. Energy (with 100 ms pulse): 800 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 60 mmResponse Time (0-90%): 4 secCooling: Forced Air with Fan (a)Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
BL-A-10W-12-ALaserPointHigh Speed Thermal SensorsMax. Average Power: 10 WMax. Energy: 10 JAbsorber Spectral Range: 0.5 – 1.1 µmAperture: 12x12 mmNatural Response Time (0-90%): Typ. 90 ms (min. 50 ms – max. 120 ms)Cooling: Convection (a)Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
BL-A-25W-16-KLaserPointHigh Speed Thermal SensorsMax. Average Power: 25 WMax. Energy: 5 JAbsorber Spectral Range: 0.2 - 25 µmAperture: 16 x 16 mmNatural Response Time (0-90%): Typ. 90ms (min. 50 ms – max. 120 ms)Cooling: Forced Air (a)Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
BL-A-50W-12-ALaserPointHigh Speed Thermal SensorsMax. Average Power: 50 WMax. Energy: 10 JAbsorber Spectral Range: 0.5 – 1.1 µmAperture: 12 x 12 mmNatural Response Time (0-90%): Typ. 90ms (min. 50 ms – max. 120 ms)Cooling: Forced Air (a)Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
BL-A-5W-12-ALaserPointHigh Speed Thermal SensorsMax. Average Power: 5 WMax. Energy: 10 JAbsorber Spectral Range: 0.5 – 1.1 µmAperture: 12 x 12 mmNatural Response Time (0-90%): Typ. 90 ms (min. 50 ms – max. 120 ms)Cooling: Convection (a)Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
BL-A-5W-16-KLaserPointHigh Speed Thermal SensorsMax. Average Power (1): 5 WMax. Energy: 5 JAbsorber Spectral Range: 0.2 - 25 µmAperture: 16 x 16 mmNatural Response Time (0-90%): Typ. 90ms (min. 50 ms – max. 120 ms)Cooling: Convection (a)Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
BL-A-8W-16-KLaserPointHigh Speed Thermal SensorsMax. Average Power (1): 8 WMax. Energy: 5 JAbsorber Spectral Range: 0.2 - 25 µmAperture: 16 x 16 mmNatural Response Time (0-90%): Typ. 90ms (min. 50 ms – max. 120 ms)Cooling: Convection (a)Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
BL-W-100W-12-ALaserPointHigh Speed Thermal SensorsMax. Average Power: 100 WMax. Energy: 10 JAbsorber Spectral Range: 0.5 – 1.1 µmAperture: 12 x 12 mmNatural Response Time (0-90%): Typ. 90ms (min. 50 ms – max. 120 ms)Cooling: Water (a)Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
BL-W-50W-16-KLaserPointHigh Speed Thermal SensorsMax. Average Power: 50 WMax. Energy: 5 JAbsorber Spectral Range: 0.2 - 25 µmAperture: 16 x 16 mmNatural Response Time (0-90%): Typ. 90ms (min. 50 ms – max. 120 ms)Cooling: Water (a)Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
BM-A-10W-10-BLaserPointHigh Speed Thermal SensorsMax. Average Power: 10 WMax. Energy: 20 mJAbsorber Spectral Range: 0.5 – 1.1 µmAperture: 10 x 10 mm—Cooling: Convection (b)—Power Calibration Uncertainty: ± 5%View family documentation
BM-A-10W-10-B-ENHLaserPointHigh Speed Thermal SensorsMax. Average Power: 10 WMax. Energy: 20 mJAbsorber Spectral Range: 0.5 – 1.1 µmAperture: 10 x 10 mm—Cooling: Convection (b)—Power Calibration Uncertainty: ± 5%View family documentation
BM-A-15W-14-TLaserPointHigh Speed Thermal SensorsMax. Average Power: 15 WMax. Energy: 10 mJAbsorber Spectral Range: 0.2 - 11 µmAperture: 14 x 14 mm—Cooling: Forced Air (c)Cable length - connector: 2 m - Hirose IXPower Calibration Uncertainty: ± 5%View family documentation
BM-A-15W-14-T-ENHLaserPointHigh Speed Thermal SensorsMax. Average Power: 15 WMax. Energy: 10 mJAbsorber Spectral Range: 0.2 - 11 µmAperture: 14 x 14 mm—Cooling: Forced Air (c)Cable length - connector: 2 m - Hirose IXPower Calibration Uncertainty: ± 5%View family documentation
BM-A-15W-14-TXLaserPointHigh-speed thermal power/energy sensor1 mW–15 W, continuous average power1–40 µJ at 1064 nm, pulse duration <10 ns; 40–1000 µJ at 1064 nm, pulse duration 10 ms0.2–11 µm absorber range; calibration wavelengths selected separately14 × 14 mm; minimum beam diameter 3 mm—Forced air; recommended ambient 10–35 °CHirose IX sensor connection to HSM-1000±5% power / ±5% energy calibration uncertaintyView family documentation
BM-A-15W-14-TX-ENHLaserPointHigh-speed thermal power/energy sensor and HSM-1000 enhanced meter system1 mW–15 W, continuous average power0.25–40 µJ at 1064 nm, pulse duration <10 ns; 20–1000 µJ at 1064 nm, pulse duration 10 ms0.2–11 µm absorber range; calibration wavelengths selected separately14 × 14 mm; minimum beam diameter 3 mm—Forced air; recommended ambient 10–35 °CHirose IX sensor connection to HSM-1000±5% power / ±5% energy calibration uncertaintyView family documentation
BM-A-25W-10-BLaserPointHigh Speed Thermal SensorsMax. Average Power: 25 WMax. Energy: 20 mJAbsorber Spectral Range: 0.5 – 1.1 µmAperture: 10 x 10 mm—Cooling: Forced Air (b)—Power Calibration Uncertainty: ± 5%View family documentation
BM-A-25W-10-B-ENHLaserPointHigh Speed Thermal SensorsMax. Average Power: 25 WMax. Energy: 20 mJAbsorber Spectral Range: 0.5 – 1.1 µmAperture: 10 x 10 mm—Cooling: Forced Air (b)—Power Calibration Uncertainty: ± 5%View family documentation
BM-A-5W-10-BLaserPointHigh Speed Thermal SensorsMax. Average Power: 5 WMax. Energy: 20 mJAbsorber Spectral Range: 0.5 – 1.1 µmAperture: 10 x 10 mm—Cooling: Convection (b)—Power Calibration Uncertainty: ± 5%View family documentation
BM-A-5W-10-B-ENHLaserPointHigh Speed Thermal SensorsMax. Average Power: 5 WMax. Energy: 20 mJAbsorber Spectral Range: 0.5 - 11 µmAperture: 10 x 10 mm—Cooling: Convection (b)—Power Calibration Uncertainty: ± 5%View family documentation
BM-A-5W-14-TLaserPointHigh Speed Thermal SensorsMax. Average Power (1): 5 WMax. Energy: 10 mJAbsorber Spectral Range: 0.2 - 11 µmAperture: 14 x 14 mm—Cooling: Convection (c)Cable length - connector: 2 m - Hirose IXPower Calibration Uncertainty: ± 5%View family documentation
BM-A-5W-14-T-ENHLaserPointHigh Speed Thermal SensorsMax. Average Power (1): 5 WMax. Energy: 10 mJAbsorber Spectral Range: 0.2 - 11 µmAperture: 14 x 14 mm—Cooling: Convection (c)Cable length - connector: 2 m - Hirose IXPower Calibration Uncertainty: ± 5%View family documentation
BM-A-5W-14-TXLaserPointHigh-speed thermal power/energy sensor1 mW–5 W, continuous average power1–40 µJ at 1064 nm, pulse duration <10 ns; 40–1000 µJ at 1064 nm, pulse duration 10 ms0.2–11 µm absorber range; calibration wavelengths selected separately14 × 14 mm; minimum beam diameter 3 mm—Convection; recommended ambient 10–30 °CHirose IX sensor connection to HSM-1000±5% power / ±5% energy calibration uncertaintyView family documentation
BM-A-5W-14-TX-ENHLaserPointHigh-speed thermal power/energy sensor and HSM-1000 enhanced meter system1 mW–5 W, continuous average power0.25–40 µJ at 1064 nm, pulse duration <10 ns; 20–1000 µJ at 1064 nm, pulse duration 10 ms0.2–11 µm absorber range; calibration wavelengths selected separately14 × 14 mm; minimum beam diameter 3 mm—Convection; recommended ambient 10–30 °CHirose IX sensor connection to HSM-1000±5% power / ±5% energy calibration uncertaintyView family documentation
BM-A-8W-14-TLaserPointHigh Speed Thermal SensorsMax. Average Power (1): 8 WMax. Energy: 10 mJAbsorber Spectral Range: 0.2 - 11 µmAperture: 14 x 14 mm—Cooling: Convection (c)Cable length - connector: 2 m - Hirose IXPower Calibration Uncertainty: ± 5%View family documentation
BM-A-8W-14-T-ENHLaserPointHigh Speed Thermal SensorsMax. Average Power (1): 8 WMax. Energy: 10 mJAbsorber Spectral Range: 0.2 - 11 µmAperture: 14 x 14 mm—Cooling: Convection (c)Cable length - connector: 2 m - Hirose IXPower Calibration Uncertainty: ± 5%View family documentation
BM-A-8W-14-TXLaserPointHigh-speed thermal power/energy sensor1 mW–8 W, continuous average power1–40 µJ at 1064 nm, pulse duration <10 ns; 40–1000 µJ at 1064 nm, pulse duration 10 ms0.2–11 µm absorber range; calibration wavelengths selected separately14 × 14 mm; minimum beam diameter 3 mm—Convection; recommended ambient 10–30 °CHirose IX sensor connection to HSM-1000±5% power / ±5% energy calibration uncertaintyView family documentation
BM-A-8W-14-TX-ENHLaserPointHigh-speed thermal power/energy sensor and HSM-1000 enhanced meter system1 mW–8 W, continuous average power0.25–40 µJ at 1064 nm, pulse duration <10 ns; 20–1000 µJ at 1064 nm, pulse duration 10 ms0.2–11 µm absorber range; calibration wavelengths selected separately14 × 14 mm; minimum beam diameter 3 mm—Convection; recommended ambient 10–30 °CHirose IX sensor connection to HSM-1000±5% power / ±5% energy calibration uncertaintyView family documentation
BM-W-20W-14-TLaserPointHigh Speed Thermal SensorsMax. Average Power: 20 WMax. Energy: 10 mJAbsorber Spectral Range: 0.2 - 11 µmAperture: 14 x 14 mm—Cooling: Water (c)Cable length - connector: 2 m - Hirose IXPower Calibration Uncertainty: ± 5%View family documentation
BM-W-20W-14-T-ENHLaserPointHigh Speed Thermal SensorsMax. Average Power: 20 WMax. Energy: 10 mJAbsorber Spectral Range: 0.2 - 11 µmAperture: 14 x 14 mm—Cooling: Water (c)Cable length - connector: 2 m - Hirose IXPower Calibration Uncertainty: ± 5%View family documentation
BM-W-20W-14-TXLaserPointHigh-speed thermal power/energy sensor1 mW–20 W, continuous average power1–40 µJ at 1064 nm, pulse duration <10 ns; 40–1000 µJ at 1064 nm, pulse duration 10 ms0.2–11 µm absorber range; calibration wavelengths selected separately14 × 14 mm; minimum beam diameter 3 mm—Water: 1–4 l/min at 10–25 °C; water temperature variation <1 °C/minHirose IX sensor connection to HSM-1000±5% power / ±5% energy calibration uncertaintyView family documentation
BM-W-20W-14-TX-ENHLaserPointHigh-speed thermal power/energy sensor and HSM-1000 enhanced meter system1 mW–20 W, continuous average power0.25–40 µJ at 1064 nm, pulse duration <10 ns; 20–1000 µJ at 1064 nm, pulse duration 10 ms0.2–11 µm absorber range; calibration wavelengths selected separately14 × 14 mm; minimum beam diameter 3 mm—Water: 1–4 l/min at 10–25 °C; water temperature variation <1 °C/minHirose IX sensor connection to HSM-1000±5% power / ±5% energy calibration uncertaintyView family documentation
BM-W-50W-10-BLaserPointHigh Speed Thermal SensorsMax. Average Power: 50 WMax. Energy: 20 mJAbsorber Spectral Range: 0.5 – 1.1 µmAperture: 10 x 10 mm—Cooling: Water (b)—Power Calibration Uncertainty: ± 5%View family documentation
BM-W-50W-10-B-ENHLaserPointHigh Speed Thermal SensorsMax. Average Power: 50 WMax. Energy: 20 mJAbsorber Spectral Range: 0.5 – 1.1 µmAperture: 10 x 10 mm—Cooling: Water (b)—Power Calibration Uncertainty: ± 5%View family documentation
Cronos LP1.5LaserPointPower ProbesMax. Average Power: 1500 WMax Energy Density (1): 5ms pulse width: 36 J/cm² 10µs pulse width: 1.2 J/cm² 10ns pulse width: 0.3 J/cm²Absorber Spectral Range: 0.19 - 11 µmAperture: 40 mm—Cooling: Convection—Power Calibration Uncertainty: ± 4%View family documentation
Cronos LP10LaserPointPower ProbesMax. Average Power: 10 kWMax Energy Density (1): 5ms pulse width: 36 J/cm² 10µs pulse width: 1.2 J/cm² 10ns pulse width: 0.3 J/cm²Absorber Spectral Range: 0.19 - 11 µmAperture: 65 mm—Cooling: Convection—Power Calibration Uncertainty: ± 4%View family documentation
Cronos LP5.0LaserPointPower ProbesMax. Average Power: 5 kWMax Energy Density (1): 5ms pulse width: 36 J/cm² 10µs pulse width: 1.2 J/cm² 10ns pulse width: 0.3 J/cm²Absorber Spectral Range: 0.19 - 11 µmAperture: 55 mm—Cooling: Convection—Power Calibration Uncertainty: ± 4%View family documentation
EXTREME-20LaserPointPower ProbesMax. Average Power: 20 kW (a)Max Energy Density (3): 3000 J / cm2 (d)Absorber Spectral Range: 1050 nm - 1090 nmAperture: ø 35 mmResponse Time: 4-10 secCooling: ConvectionCable length - connector: 5 m – DB15Power Calibration Uncertainty (1): ± 5%View family documentation
EXTREME-40LaserPointHandheld high-power laser measurement probe40 kW at 100 ms; 20 kW at 200 ms; 8 kW at 500 ms. Minimum 500 W at 500 ms; use exact-mode limits.—1050–1090 nm absorber range; calibrated at 1070 nm35 mm diameter4–10 sConvectionDB15, 5 m cable on current product pagePower calibration ±5%; pulse timing must be controlled preciselyView family documentation
Fit-200LaserPointPower ProbesMax. Average Power: 200 WMax Energy Density (2): 5ms pulse width: 36 J/cm² 10µs pulse width: 1.2 J/cm² 10ns pulse width: 0.3 J/cm²Absorber Spectral Range: 0.19 - 11 µmAperture: 20 mm—Cooling: Convection—Power Calibration Uncertainty: ± 3%View family documentation
Fit-50LaserPointPower ProbesMax. Average Power: 50 WMax Energy Density (2): 5ms pulse width: 36 J/cm² 10µs pulse width: 1.2 J/cm² 10ns pulse width: 0.3 J/cm²Absorber Spectral Range: 0.19 - 11 µmAperture: 20 mm—Cooling: Convection—Power Calibration Uncertainty: ± 3%View family documentation
Fit-500LaserPointPower ProbesMax. Average Power: 500 WMax Energy Density (2): 5ms pulse width: 36 J/cm² 10µs pulse width: 1.2 J/cm² 10ns pulse width: 0.3 J/cm²Absorber Spectral Range: 0.19 - 11 µmAperture: 25 mm—Cooling: Convection—Power Calibration Uncertainty: ± 3%View family documentation
Fit-IPL-RLaserPointPower ProbesMax. Average Power: 100 WMax. Energy (with 100 ms pulse): 350 JAbsorber Spectral Range: 0.4 - 2.1 µmAperture: 20 x 60 mm (1)—Cooling: Convection—Power Calibration Uncertainty: ± 3%View family documentation
PD-50-D9-IRLaserPointPhotodiodesMax. Average Power (1): 40 mW—Calibration spectral range: 800 - 1800 nmAperture: 9.5 mmResponse Time (0-90%): 0.25 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 7% @800-1000nm, ±3% @1000-1650nm, ±5% @1650-1800nmView family documentation
PD-50-D9-UVLaserPointPhotodiodesMax. Average Power (1): 50 mW—Calibration spectral range: 200 - 1100 nmAperture: 9.5 mmResponse Time (0-90%): 0.25 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 5% @200-400nm, ±3% @400-1000nm, ±5% @1000-1100nmView family documentation
PD-50-D9-VISLaserPointPhotodiodesMax. Average Power (1): 50 mW—Calibration spectral range: 400 - 1100 nmAperture: 9.5 mmResponse Time (0-90%): 0.25 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 5% @400-500nm, ±3% @500-1000nm, ±5% @1000-1100nmView family documentation
PD-500-D9-VISLaserPointPhotodiodesMax. Average Power (1): 500 mW—Calibration spectral range: 400 - 1100 nmAperture: 9.5 mmResponse Time (0-90%): 0.25 secCooling: ConvectionCable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 5% @400-500nm, ±3% @500-1000nm, ±5% @1000-1100nmView family documentation
W-1500-D40-HPBLaserPointThermal SensorsMax. Average Power: 1500 WMax. Energy (with 100 ms pulse): 2250 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 40 mmResponse Time (0-90%): 4 secCooling: Water (a)Cable length - connector: 5.0 m - DB15 5.0 m – USB (U option) 5.0 m - RS232 (R option)Power Calibration Uncertainty: ± 5%View family documentation
W-1500-D40-SHCLaserPointThermal SensorsMax. Average Power: 1500 WMax. Energy (with 100 ms pulse): 2250 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 40 mmResponse Time (0-90%): 4 secCooling: Water (a)Cable length - connector: 5.0 m - DB15 5.0 m – USB (U option) 5.0 m - RS232 (R option)Power Calibration Uncertainty: ± 5%View family documentation
W-200-D40-HPBLaserPointThermal SensorsMax. Average Power: 200 WMax. Energy (with 100 ms pulse): 300 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 40 mmResponse Time (0-90%): 2 secCooling: Water (a)Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
W-200-D40-SHCLaserPointThermal SensorsMax. Average Power: 200 WMax. Energy (with 100 ms pulse): 300 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 40 mmResponse Time (0-90%): 2 secCooling: Water (a)Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
W-3000-D55-HPBLaserPointThermal SensorsMax. Average Power: 3 kWMax. Energy (with 100 ms pulse): n.a.Absorber Spectral Range: 0.19 - 11 µmAperture: 55 mmResponse Time (0-90%): 5 secCooling: Water (a)Cable length - connector: 5.0 m - DB15 5.0 m – USB (U option) 5.0 m - RS232 (R option)Power Calibration Uncertainty: ± 5%View family documentation
W-3000-D55-SHCLaserPointThermal SensorsMax. Average Power: 3 kWMax. Energy (with 100 ms pulse): n.a.Absorber Spectral Range: 0.19 - 11 µmAperture: 55 mmResponse Time (0-90%): 5 secCooling: Water (a)Cable length - connector: 5.0 m - DB15 5.0 m – USB (U option) 5.0 m - RS232 (R option)Power Calibration Uncertainty: ± 5%View family documentation
W-600-D30-HPBLaserPointThermal SensorsMax. Average Power: 600 WMax. Energy (with 100 ms pulse): 800 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 30 mmResponse Time (0-90%): 2 secCooling: Water (a)Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
W-600-D30-SHCLaserPointThermal SensorsMax. Average Power: 600 WMax. Energy (with 100 ms pulse): 800 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 30 mmResponse Time (0-90%): 2 secCooling: Water (a)Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
W-600-D70-HPBLaserPointThermal SensorsMax. Average Power: 600 WMax. Energy (with 100 ms pulse): 800 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 70 mmResponse Time (0-90%): 2 secCooling: Water (a)Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
W-600-D70-SHCLaserPointThermal SensorsMax. Average Power: 600 WMax. Energy (with 100 ms pulse): 800 JAbsorber Spectral Range: 0.19 - 11 µmAperture: 70 mmResponse Time (0-90%): 2 secCooling: Water (a)Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option)Power Calibration Uncertainty: ± 3%View family documentation
W-6000-D55-SHCLaserPointThermal SensorsMax. Average Power: 6 kWMax. Energy (with 100 ms pulse): n.a.Absorber Spectral Range: 0.19 - 11 µmAperture: 55 mmResponse Time (0-90%): 3.5 secCooling: Water (a)Cable length - connector: 5.0 m - DB15 5.0 m – USB (U option) 5.0 m - RS232 (R option)Power Calibration Uncertainty: ± 5%View family documentation

Looking for a specific brand or product?

Contact our technical team and we will help you find the most suitable solution for your application.

Address