EXTREME-40

Handheld high-power laser measurement probe; 40 kW at 100 ms; 20 kW at 200 ms; 8 kW at 500 ms. Minimum 500 W at 500 ms; use exact-mode limits.

SKU: LPT-EXTREME-40 Category:
Contact us to inquire about this product

If you love this product and wish for a customized quote contact us at number +34 91 3854 395 and we will be happy to provide you with more info!

Product overview

EXTREME-40 is the handheld high-power laser measurement probe identified by this exact Excel SKU. Power range, pulse duration, absorber response and calibration uncertainty retain the manufacturer conditions. The product page is used for current configuration details; the original catalogue is shared family documentation.

Documentation

LaserPoint EXTREME family catalogue — 2024 revision 1

ManufacturerLaserPoint
CoolingConvection
Spectral range and conditions1050–1090 nm absorber range; calibrated at 1070 nm
Data interfaceDB15, 5 m cable on current product page
Family documentationView family documentation
DimensionsØ115 × 85 mm
Product typeHandheld high-power laser measurement probe
Measured power and conditions40 kW at 100 ms; 20 kW at 200 ms; 8 kW at 500 ms. Minimum 500 W at 500 ms; use exact-mode limits.
Response time and conditions4–10 s
Active aperture35 mm diameter
Measurement uncertaintyPower calibration ±5%; pulse timing must be controlled precisely
Weight and configuration2.55 kg
Model configuration details
Requested pulse duration (1) 100, 200, 500 ms
Max. Average Power 40 kW (a)
Power Resolution 10 W
Noise Equivalent Power (NEP) 10 W (c)
Response Time 4-10 sec
Power Calibration Uncertainty (1) ± 5%
Power Linearity (2) ± 2%
Repeatability ± 1%
Aperture ø 35 mm
Type C
Absorber Spectral Range 1050 - 1090 nm
Calibration Spectral Range 1070 nm
Max Power Density (3) 15 kW / cm2 @ 20 kW (d) 12 kW / cm2 @ 40 kW (e)
Max Energy Density (3) 3000 J / cm2 (d)
Cooling Convection
Weight 2.55 kg
Dimension ø 115 mm x 85 mm
Cable length - connector 5 m – DB15
(1) Laser pulse duration must be controlled with high precision: shorter or longer duration will directly affect measurement uncertainty. Recommended Laser rise time < 200 µs. (2) Detector centrally irradiated, 50% of useful surface. (3) Damage thresholds also depend on power level. (a) pulse duration 100 ms (20 kW with 200 ms) (8 kW with 500 ms). (b) pulse duration 500 ms (1 kW with 200 ms) (2 kW wih 500 ms). (c) pulse duration 500 ms (25 W with 200 ms) (50W with 500 ms). (d) 200 ms pulse duration. (e) 100 ms pulse duration.
Power and pulse conditions 40 kW at 100 ms; 20 kW at 200 ms; 8 kW at 500 ms. Minimum 500 W at 500 ms; use exact-mode limits.
Current-page corrections Current exact-model page specifies 40 kW at 100 ms and 12 kW/cm² at 40 kW / 100 ms. The older family catalogue has copied 20 kW values in parts of the EXTREME-40 column.
Pulse control Recommended laser rise time <200 µs. Probe response time is distinct from the requested laser exposure duration.
Measurable power 40 kW at 100 ms; 20 kW at 200 ms; 8 kW at 500 ms. Minimum 500 W at 500 ms; use exact-mode limits.
Spectral range 1050–1090 nm absorber range; calibrated at 1070 nm
Active aperture 35 mm diameter
Response time 4–10 s
Interface DB15, 5 m cable on current product page
Measurement uncertainty Power calibration ±5%; pulse timing must be controlled precisely
Dimensions Ø115 × 85 mm
Product weight 2.55 kg

I have read and accepted your terms and conditions and privacy policy