Laser Power & Energy Meters
LaserPoint offers advanced solutions for the precise measurement of power and energy in laser systems. Their range of thermal sensors covers applications from low-power lasers to high-power lasers up to 40 kW, without the need for water cooling. Notable products include the high-speed BLINK sensor, ideal for ultrafast lasers with repetition rates up to 1 MHz and femtosecond pulse durations, and the Pulse Controller, designed for pulse-to-pulse energy measurement in fast and ultrafast lasers. With over 30 years of experience, LaserPoint is a reliable tool for professionals across various industries.
Iberoptics is distributor of LaserPoint solutions, offering expert guidance and local support to help customers select the most suitable power and energy meters for their laser applications.
| 10-BB-D12-L | LaserPoint | Thermal Sensors | Max. Average Power: 10 W | Max. Energy (with 100 ms pulse): 10 J | Absorber Spectral Range: 0.4 - 2 µm | Aperture: 12 mm | Response Time (0-90%): 3 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 10-BB-D25 | LaserPoint | Thermal Sensors | Max. Average Power: 10 W | Max. Energy (with 100 ms pulse): 10 J | Absorber Spectral Range: 0.4 - 5.2 µm | Aperture: 25 mm | Response Time (0-90%): 3 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| 10-UVA-D25 | LaserPoint | Thermal Sensors | Max. Average Power: 10 W | Max. Energy (with 100 ms pulse): 10 J | Absorber Spectral Range: 0.25 - 0.4 µm | Aperture: 25 mm | Response Time (0-90%): 3 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| 10-UVC-D25 | LaserPoint | Thermal Sensors | Max. Average Power: 10 W | Max. Energy (with 100 ms pulse): 10 J | Absorber Spectral Range: 0.19 - 0.25 µm | Aperture: 25 mm | Response Time (0-90%): 3 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| 20-BB-D40 | LaserPoint | Thermal Sensors | Max. Average Power: 20 W | Max. Energy (with 100 ms pulse): 20 J | Absorber Spectral Range: 0.4 - 5.2 µm | Aperture: 40 mm | Response Time (0-90%): 3 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| 20-UVA-D40 | LaserPoint | Thermal Sensors | Max. Average Power: 20 W | Max. Energy (with 100 ms pulse): 20 J | Absorber Spectral Range: 0.25 - 0.4 µm | Aperture: 40 mm | Response Time (0-90%): 3 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| 20-UVC-D40 | LaserPoint | Thermal Sensors | Max. Average Power: 20 W | Max. Energy (with 100 ms pulse): 20 J | Absorber Spectral Range: 0.19 - 0.25 µm | Aperture: 40 mm | Response Time (0-90%): 3 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| A-02-D12-BBF | LaserPoint | Thermal Sensors | Max. Average Power: 200 mW | Max. Energy (with 100 ms pulse): 200 mJ | Absorber Spectral Range: 0.19 - 25 µm | Aperture: 10 mm | Response Time (0-90%): 2 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| A-10-D12-DIF | LaserPoint | Thermal Sensors | Max. Average Power: 10 W | Max. Energy (with 100 ms pulse): 15 J | Absorber Spectral Range: 0.2 - 2.1 µm | Aperture: 12 mm | Response Time (0-90%): 1 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| A-10-D12-HPB | LaserPoint | Thermal Sensors | Max. Average Power: 10 W | Max. Energy (with 100 ms pulse): 15 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 12 mm | Response Time (0-90%): 0.8 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| A-10-D20-BBF | LaserPoint | Thermal Sensors | Max. Average Power: 10 W | Max. Energy (with 100 ms pulse): 15 J | Absorber Spectral Range: 0.19 - 25 µm | Aperture: 20 mm | Response Time (0-90%): 1 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| A-10-D20-HPB | LaserPoint | Thermal Sensors | Max. Average Power: 10 W | Max. Energy (with 100 ms pulse): 15 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 20 mm | Response Time (0-90%): 1 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| A-1200-D60-SHC | LaserPoint | Thermal Sensors | Max. Average Power: 1200 W | Max. Energy (with 100 ms pulse): 1200 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 60 mm | Response Time (0-90%): 6 sec | Cooling: Forced Air with Fan (a) | Cable length - connector: 5.0 m - DB15 5.0 m – USB (U option) 5.0 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| A-2-D12-BBF | LaserPoint | Thermal Sensors | Max. Average Power: 2 W | Max Energy Density (2): 5ms pulse width: 3.6 J/cm² 10µs pulse width: 0.2 J/cm² 10ns pulse width: 0.1 J/cm² | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 12 mm | Response Time (0-90%): < 1 sec | Cooling: Conduction (a) | Cable length - connector: 1.5 m - Bare wire | — | View family documentation |
| A-2-D12-HPB | LaserPoint | Thermal Sensors | Max. Average Power: 2 W | Max Energy Density (2): 5ms pulse width: 36 J/cm² 10µs pulse width: 1.2 J/cm² 10ns pulse width: 0.3 J/cm² | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 12 mm | Response Time (0-90%): < 1 sec | Cooling: Conduction (a) | Cable length - connector: 1.5 m - Bare wire | — | View family documentation |
| A-200-D25-HPB | LaserPoint | Thermal Sensors | Max. Average Power: 200 W | Max. Energy (with 100 ms pulse): 250 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 25 mm | Response Time (0-90%): 1.7 sec | Cooling: Forced Air with Fan (a) | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| A-200-D25-SHC | LaserPoint | Thermal Sensors | Max. Average Power: 200 W | Max. Energy (with 100 ms pulse): 250 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 25 mm | Response Time (0-90%): 1.7 sec | Cooling: Forced Air with Fan (a) | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| A-200-D40-HPB | LaserPoint | Thermal Sensors | Max. Average Power: 200 W | Max. Energy (with 100 ms pulse): 250 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 40 mm | Response Time (0-90%): 2 sec | Cooling: Forced Air with Fan (a) | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| A-200-D40-SHC | LaserPoint | Thermal Sensors | Max. Average Power: 200 W | Max. Energy (with 100 ms pulse): 250 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 40 mm | Response Time (0-90%): 2 sec | Cooling: Forced Air with Fan (a) | — | Power Calibration Uncertainty: ± 3% | View family documentation |
| A-200-D60-HPB | LaserPoint | Thermal Sensors | Max. Average Power: 200 W | Max. Energy (with 100 ms pulse): 250 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 60 mm | Response Time (0-90%): 3 sec | Cooling: Forced Air with Fan (a) | — | Power Calibration Uncertainty: ± 3% | View family documentation |
| A-200-D60-SHC | LaserPoint | Thermal Sensors | Max. Average Power: 200 W | Max. Energy (with 100 ms pulse): 250 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 60 mm | Response Time (0-90%): 3 sec | Cooling: Forced Air with Fan (a) | — | Power Calibration Uncertainty: ± 3% | View family documentation |
| A-30-D12-SHC-L | LaserPoint | Thermal laser power and single-shot energy sensor | 20 mW–30 W continuous; up to 45 W for at most 2 minutes | 100 mJ–45 J; 45 J maximum with 100 ms pulse | 0.2–1.1 µm | 12 mm diameter | 15 s (0–90%) | Convection | DB15; USB/RS-232 versions are separately selected options | Power calibration: ±3%; energy calibration: ±5% | View family documentation |
| A-30-D18-DIF | LaserPoint | Thermal Sensors | Max. Average Power: 30 W | Max. Energy (with 100 ms pulse): 45 J | Absorber Spectral Range: 0.2 - 2.1 µm | Aperture: 18 mm | Response Time (0-90%): 1.5 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| A-30-D25-HPB | LaserPoint | Thermal Sensors | Max. Average Power: 30 W | Max. Energy (with 100 ms pulse): 45 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 25 mm | Response Time (0-90%): 1.5 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| A-300-D60-HPB | LaserPoint | Thermal Sensors | Max. Average Power: 300 W | Max. Energy (with 100 ms pulse): 400 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 60 mm | Response Time (0-90%): 3.5 sec | Cooling: Forced Air with Fan (a) | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| A-40-D25-HPB | LaserPoint | Thermal Sensors | Max. Average Power: 40 W | Max. Energy (with 100 ms pulse): 60 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 25 mm | Response Time (0-90%): 1.5 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| A-40-D33-DIF | LaserPoint | Thermal Sensors | Max. Average Power: 40 W | Max. Energy (with 100 ms pulse): 60 J | Absorber Spectral Range: 0.2 - 2.1 µm | Aperture: 33 mm | Response Time (0-90%): 1.8 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| A-40-D40-HPB | LaserPoint | Thermal Sensors | Max. Average Power: 40 W | Max. Energy (with 100 ms pulse): 60 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 40 mm | Response Time (0-90%): 1.8 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| A-40/200-D25-HPB | LaserPoint | Thermal Sensors | Max. Average Power: 40 W | Max. Energy (with 100 ms pulse): 200 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 25 mm | Response Time (0-90%): 1.7 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| A-40/200-D40-HPB | LaserPoint | Thermal Sensors | Max. Average Power: 40 W | Max. Energy (with 100 ms pulse): 200 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 40 mm | Response Time (0-90%): 1.7 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| A-40/200-D60-HPB | LaserPoint | Thermal Sensors | Max. Average Power: 40 W | Max. Energy (with 100 ms pulse): 200 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 60 mm | Response Time (0-90%): 3 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| A-5-D12-BBF | LaserPoint | Thermal Sensors | Max. Average Power: 5 W | Max Energy Density (2): 5ms pulse width: 3.6 J/cm² 10µs pulse width: 0.2 J/cm² 10ns pulse width: 0.1 J/cm² | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 12 mm | Response Time (0-90%): < 1 sec | Cooling: Conduction (a) | Cable length - connector: 1.5 m - Bare Wire | — | View family documentation |
| A-600-D40-HPB | LaserPoint | Thermal Sensors | Max. Average Power: 600 W | Max. Energy (with 100 ms pulse): 800 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 40 mm | Response Time (0-90%): 5 sec | Cooling: Forced Air with Fan (a) | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| A-600-D60-SHC | LaserPoint | Thermal Sensors | Max. Average Power: 600 W | Max. Energy (with 100 ms pulse): 800 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 60 mm | Response Time (0-90%): 4 sec | Cooling: Forced Air with Fan (a) | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| BL-A-10W-12-A | LaserPoint | High Speed Thermal Sensors | Max. Average Power: 10 W | Max. Energy: 10 J | Absorber Spectral Range: 0.5 – 1.1 µm | Aperture: 12x12 mm | Natural Response Time (0-90%): Typ. 90 ms (min. 50 ms – max. 120 ms) | Cooling: Convection (a) | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| BL-A-25W-16-K | LaserPoint | High Speed Thermal Sensors | Max. Average Power: 25 W | Max. Energy: 5 J | Absorber Spectral Range: 0.2 - 25 µm | Aperture: 16 x 16 mm | Natural Response Time (0-90%): Typ. 90ms (min. 50 ms – max. 120 ms) | Cooling: Forced Air (a) | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| BL-A-50W-12-A | LaserPoint | High Speed Thermal Sensors | Max. Average Power: 50 W | Max. Energy: 10 J | Absorber Spectral Range: 0.5 – 1.1 µm | Aperture: 12 x 12 mm | Natural Response Time (0-90%): Typ. 90ms (min. 50 ms – max. 120 ms) | Cooling: Forced Air (a) | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| BL-A-5W-12-A | LaserPoint | High Speed Thermal Sensors | Max. Average Power: 5 W | Max. Energy: 10 J | Absorber Spectral Range: 0.5 – 1.1 µm | Aperture: 12 x 12 mm | Natural Response Time (0-90%): Typ. 90 ms (min. 50 ms – max. 120 ms) | Cooling: Convection (a) | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| BL-A-5W-16-K | LaserPoint | High Speed Thermal Sensors | Max. Average Power (1): 5 W | Max. Energy: 5 J | Absorber Spectral Range: 0.2 - 25 µm | Aperture: 16 x 16 mm | Natural Response Time (0-90%): Typ. 90ms (min. 50 ms – max. 120 ms) | Cooling: Convection (a) | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| BL-A-8W-16-K | LaserPoint | High Speed Thermal Sensors | Max. Average Power (1): 8 W | Max. Energy: 5 J | Absorber Spectral Range: 0.2 - 25 µm | Aperture: 16 x 16 mm | Natural Response Time (0-90%): Typ. 90ms (min. 50 ms – max. 120 ms) | Cooling: Convection (a) | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| BL-W-100W-12-A | LaserPoint | High Speed Thermal Sensors | Max. Average Power: 100 W | Max. Energy: 10 J | Absorber Spectral Range: 0.5 – 1.1 µm | Aperture: 12 x 12 mm | Natural Response Time (0-90%): Typ. 90ms (min. 50 ms – max. 120 ms) | Cooling: Water (a) | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| BL-W-50W-16-K | LaserPoint | High Speed Thermal Sensors | Max. Average Power: 50 W | Max. Energy: 5 J | Absorber Spectral Range: 0.2 - 25 µm | Aperture: 16 x 16 mm | Natural Response Time (0-90%): Typ. 90ms (min. 50 ms – max. 120 ms) | Cooling: Water (a) | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| BM-A-10W-10-B | LaserPoint | High Speed Thermal Sensors | Max. Average Power: 10 W | Max. Energy: 20 mJ | Absorber Spectral Range: 0.5 – 1.1 µm | Aperture: 10 x 10 mm | — | Cooling: Convection (b) | — | Power Calibration Uncertainty: ± 5% | View family documentation |
| BM-A-10W-10-B-ENH | LaserPoint | High Speed Thermal Sensors | Max. Average Power: 10 W | Max. Energy: 20 mJ | Absorber Spectral Range: 0.5 – 1.1 µm | Aperture: 10 x 10 mm | — | Cooling: Convection (b) | — | Power Calibration Uncertainty: ± 5% | View family documentation |
| BM-A-15W-14-T | LaserPoint | High Speed Thermal Sensors | Max. Average Power: 15 W | Max. Energy: 10 mJ | Absorber Spectral Range: 0.2 - 11 µm | Aperture: 14 x 14 mm | — | Cooling: Forced Air (c) | Cable length - connector: 2 m - Hirose IX | Power Calibration Uncertainty: ± 5% | View family documentation |
| BM-A-15W-14-T-ENH | LaserPoint | High Speed Thermal Sensors | Max. Average Power: 15 W | Max. Energy: 10 mJ | Absorber Spectral Range: 0.2 - 11 µm | Aperture: 14 x 14 mm | — | Cooling: Forced Air (c) | Cable length - connector: 2 m - Hirose IX | Power Calibration Uncertainty: ± 5% | View family documentation |
| BM-A-15W-14-TX | LaserPoint | High-speed thermal power/energy sensor | 1 mW–15 W, continuous average power | 1–40 µJ at 1064 nm, pulse duration <10 ns; 40–1000 µJ at 1064 nm, pulse duration 10 ms | 0.2–11 µm absorber range; calibration wavelengths selected separately | 14 × 14 mm; minimum beam diameter 3 mm | — | Forced air; recommended ambient 10–35 °C | Hirose IX sensor connection to HSM-1000 | ±5% power / ±5% energy calibration uncertainty | View family documentation |
| BM-A-15W-14-TX-ENH | LaserPoint | High-speed thermal power/energy sensor and HSM-1000 enhanced meter system | 1 mW–15 W, continuous average power | 0.25–40 µJ at 1064 nm, pulse duration <10 ns; 20–1000 µJ at 1064 nm, pulse duration 10 ms | 0.2–11 µm absorber range; calibration wavelengths selected separately | 14 × 14 mm; minimum beam diameter 3 mm | — | Forced air; recommended ambient 10–35 °C | Hirose IX sensor connection to HSM-1000 | ±5% power / ±5% energy calibration uncertainty | View family documentation |
| BM-A-25W-10-B | LaserPoint | High Speed Thermal Sensors | Max. Average Power: 25 W | Max. Energy: 20 mJ | Absorber Spectral Range: 0.5 – 1.1 µm | Aperture: 10 x 10 mm | — | Cooling: Forced Air (b) | — | Power Calibration Uncertainty: ± 5% | View family documentation |
| BM-A-25W-10-B-ENH | LaserPoint | High Speed Thermal Sensors | Max. Average Power: 25 W | Max. Energy: 20 mJ | Absorber Spectral Range: 0.5 – 1.1 µm | Aperture: 10 x 10 mm | — | Cooling: Forced Air (b) | — | Power Calibration Uncertainty: ± 5% | View family documentation |
| BM-A-5W-10-B | LaserPoint | High Speed Thermal Sensors | Max. Average Power: 5 W | Max. Energy: 20 mJ | Absorber Spectral Range: 0.5 – 1.1 µm | Aperture: 10 x 10 mm | — | Cooling: Convection (b) | — | Power Calibration Uncertainty: ± 5% | View family documentation |
| BM-A-5W-10-B-ENH | LaserPoint | High Speed Thermal Sensors | Max. Average Power: 5 W | Max. Energy: 20 mJ | Absorber Spectral Range: 0.5 - 11 µm | Aperture: 10 x 10 mm | — | Cooling: Convection (b) | — | Power Calibration Uncertainty: ± 5% | View family documentation |
| BM-A-5W-14-T | LaserPoint | High Speed Thermal Sensors | Max. Average Power (1): 5 W | Max. Energy: 10 mJ | Absorber Spectral Range: 0.2 - 11 µm | Aperture: 14 x 14 mm | — | Cooling: Convection (c) | Cable length - connector: 2 m - Hirose IX | Power Calibration Uncertainty: ± 5% | View family documentation |
| BM-A-5W-14-T-ENH | LaserPoint | High Speed Thermal Sensors | Max. Average Power (1): 5 W | Max. Energy: 10 mJ | Absorber Spectral Range: 0.2 - 11 µm | Aperture: 14 x 14 mm | — | Cooling: Convection (c) | Cable length - connector: 2 m - Hirose IX | Power Calibration Uncertainty: ± 5% | View family documentation |
| BM-A-5W-14-TX | LaserPoint | High-speed thermal power/energy sensor | 1 mW–5 W, continuous average power | 1–40 µJ at 1064 nm, pulse duration <10 ns; 40–1000 µJ at 1064 nm, pulse duration 10 ms | 0.2–11 µm absorber range; calibration wavelengths selected separately | 14 × 14 mm; minimum beam diameter 3 mm | — | Convection; recommended ambient 10–30 °C | Hirose IX sensor connection to HSM-1000 | ±5% power / ±5% energy calibration uncertainty | View family documentation |
| BM-A-5W-14-TX-ENH | LaserPoint | High-speed thermal power/energy sensor and HSM-1000 enhanced meter system | 1 mW–5 W, continuous average power | 0.25–40 µJ at 1064 nm, pulse duration <10 ns; 20–1000 µJ at 1064 nm, pulse duration 10 ms | 0.2–11 µm absorber range; calibration wavelengths selected separately | 14 × 14 mm; minimum beam diameter 3 mm | — | Convection; recommended ambient 10–30 °C | Hirose IX sensor connection to HSM-1000 | ±5% power / ±5% energy calibration uncertainty | View family documentation |
| BM-A-8W-14-T | LaserPoint | High Speed Thermal Sensors | Max. Average Power (1): 8 W | Max. Energy: 10 mJ | Absorber Spectral Range: 0.2 - 11 µm | Aperture: 14 x 14 mm | — | Cooling: Convection (c) | Cable length - connector: 2 m - Hirose IX | Power Calibration Uncertainty: ± 5% | View family documentation |
| BM-A-8W-14-T-ENH | LaserPoint | High Speed Thermal Sensors | Max. Average Power (1): 8 W | Max. Energy: 10 mJ | Absorber Spectral Range: 0.2 - 11 µm | Aperture: 14 x 14 mm | — | Cooling: Convection (c) | Cable length - connector: 2 m - Hirose IX | Power Calibration Uncertainty: ± 5% | View family documentation |
| BM-A-8W-14-TX | LaserPoint | High-speed thermal power/energy sensor | 1 mW–8 W, continuous average power | 1–40 µJ at 1064 nm, pulse duration <10 ns; 40–1000 µJ at 1064 nm, pulse duration 10 ms | 0.2–11 µm absorber range; calibration wavelengths selected separately | 14 × 14 mm; minimum beam diameter 3 mm | — | Convection; recommended ambient 10–30 °C | Hirose IX sensor connection to HSM-1000 | ±5% power / ±5% energy calibration uncertainty | View family documentation |
| BM-A-8W-14-TX-ENH | LaserPoint | High-speed thermal power/energy sensor and HSM-1000 enhanced meter system | 1 mW–8 W, continuous average power | 0.25–40 µJ at 1064 nm, pulse duration <10 ns; 20–1000 µJ at 1064 nm, pulse duration 10 ms | 0.2–11 µm absorber range; calibration wavelengths selected separately | 14 × 14 mm; minimum beam diameter 3 mm | — | Convection; recommended ambient 10–30 °C | Hirose IX sensor connection to HSM-1000 | ±5% power / ±5% energy calibration uncertainty | View family documentation |
| BM-W-20W-14-T | LaserPoint | High Speed Thermal Sensors | Max. Average Power: 20 W | Max. Energy: 10 mJ | Absorber Spectral Range: 0.2 - 11 µm | Aperture: 14 x 14 mm | — | Cooling: Water (c) | Cable length - connector: 2 m - Hirose IX | Power Calibration Uncertainty: ± 5% | View family documentation |
| BM-W-20W-14-T-ENH | LaserPoint | High Speed Thermal Sensors | Max. Average Power: 20 W | Max. Energy: 10 mJ | Absorber Spectral Range: 0.2 - 11 µm | Aperture: 14 x 14 mm | — | Cooling: Water (c) | Cable length - connector: 2 m - Hirose IX | Power Calibration Uncertainty: ± 5% | View family documentation |
| BM-W-20W-14-TX | LaserPoint | High-speed thermal power/energy sensor | 1 mW–20 W, continuous average power | 1–40 µJ at 1064 nm, pulse duration <10 ns; 40–1000 µJ at 1064 nm, pulse duration 10 ms | 0.2–11 µm absorber range; calibration wavelengths selected separately | 14 × 14 mm; minimum beam diameter 3 mm | — | Water: 1–4 l/min at 10–25 °C; water temperature variation <1 °C/min | Hirose IX sensor connection to HSM-1000 | ±5% power / ±5% energy calibration uncertainty | View family documentation |
| BM-W-20W-14-TX-ENH | LaserPoint | High-speed thermal power/energy sensor and HSM-1000 enhanced meter system | 1 mW–20 W, continuous average power | 0.25–40 µJ at 1064 nm, pulse duration <10 ns; 20–1000 µJ at 1064 nm, pulse duration 10 ms | 0.2–11 µm absorber range; calibration wavelengths selected separately | 14 × 14 mm; minimum beam diameter 3 mm | — | Water: 1–4 l/min at 10–25 °C; water temperature variation <1 °C/min | Hirose IX sensor connection to HSM-1000 | ±5% power / ±5% energy calibration uncertainty | View family documentation |
| BM-W-50W-10-B | LaserPoint | High Speed Thermal Sensors | Max. Average Power: 50 W | Max. Energy: 20 mJ | Absorber Spectral Range: 0.5 – 1.1 µm | Aperture: 10 x 10 mm | — | Cooling: Water (b) | — | Power Calibration Uncertainty: ± 5% | View family documentation |
| BM-W-50W-10-B-ENH | LaserPoint | High Speed Thermal Sensors | Max. Average Power: 50 W | Max. Energy: 20 mJ | Absorber Spectral Range: 0.5 – 1.1 µm | Aperture: 10 x 10 mm | — | Cooling: Water (b) | — | Power Calibration Uncertainty: ± 5% | View family documentation |
| Cronos LP1.5 | LaserPoint | Power Probes | Max. Average Power: 1500 W | Max Energy Density (1): 5ms pulse width: 36 J/cm² 10µs pulse width: 1.2 J/cm² 10ns pulse width: 0.3 J/cm² | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 40 mm | — | Cooling: Convection | — | Power Calibration Uncertainty: ± 4% | View family documentation |
| Cronos LP10 | LaserPoint | Power Probes | Max. Average Power: 10 kW | Max Energy Density (1): 5ms pulse width: 36 J/cm² 10µs pulse width: 1.2 J/cm² 10ns pulse width: 0.3 J/cm² | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 65 mm | — | Cooling: Convection | — | Power Calibration Uncertainty: ± 4% | View family documentation |
| Cronos LP5.0 | LaserPoint | Power Probes | Max. Average Power: 5 kW | Max Energy Density (1): 5ms pulse width: 36 J/cm² 10µs pulse width: 1.2 J/cm² 10ns pulse width: 0.3 J/cm² | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 55 mm | — | Cooling: Convection | — | Power Calibration Uncertainty: ± 4% | View family documentation |
| EXTREME-20 | LaserPoint | Power Probes | Max. Average Power: 20 kW (a) | Max Energy Density (3): 3000 J / cm2 (d) | Absorber Spectral Range: 1050 nm - 1090 nm | Aperture: ø 35 mm | Response Time: 4-10 sec | Cooling: Convection | Cable length - connector: 5 m – DB15 | Power Calibration Uncertainty (1): ± 5% | View family documentation |
| EXTREME-40 | LaserPoint | Handheld high-power laser measurement probe | 40 kW at 100 ms; 20 kW at 200 ms; 8 kW at 500 ms. Minimum 500 W at 500 ms; use exact-mode limits. | — | 1050–1090 nm absorber range; calibrated at 1070 nm | 35 mm diameter | 4–10 s | Convection | DB15, 5 m cable on current product page | Power calibration ±5%; pulse timing must be controlled precisely | View family documentation |
| Fit-200 | LaserPoint | Power Probes | Max. Average Power: 200 W | Max Energy Density (2): 5ms pulse width: 36 J/cm² 10µs pulse width: 1.2 J/cm² 10ns pulse width: 0.3 J/cm² | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 20 mm | — | Cooling: Convection | — | Power Calibration Uncertainty: ± 3% | View family documentation |
| Fit-50 | LaserPoint | Power Probes | Max. Average Power: 50 W | Max Energy Density (2): 5ms pulse width: 36 J/cm² 10µs pulse width: 1.2 J/cm² 10ns pulse width: 0.3 J/cm² | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 20 mm | — | Cooling: Convection | — | Power Calibration Uncertainty: ± 3% | View family documentation |
| Fit-500 | LaserPoint | Power Probes | Max. Average Power: 500 W | Max Energy Density (2): 5ms pulse width: 36 J/cm² 10µs pulse width: 1.2 J/cm² 10ns pulse width: 0.3 J/cm² | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 25 mm | — | Cooling: Convection | — | Power Calibration Uncertainty: ± 3% | View family documentation |
| Fit-IPL-R | LaserPoint | Power Probes | Max. Average Power: 100 W | Max. Energy (with 100 ms pulse): 350 J | Absorber Spectral Range: 0.4 - 2.1 µm | Aperture: 20 x 60 mm (1) | — | Cooling: Convection | — | Power Calibration Uncertainty: ± 3% | View family documentation |
| PD-50-D9-IR | LaserPoint | Photodiodes | Max. Average Power (1): 40 mW | — | Calibration spectral range: 800 - 1800 nm | Aperture: 9.5 mm | Response Time (0-90%): 0.25 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 7% @800-1000nm, ±3% @1000-1650nm, ±5% @1650-1800nm | View family documentation |
| PD-50-D9-UV | LaserPoint | Photodiodes | Max. Average Power (1): 50 mW | — | Calibration spectral range: 200 - 1100 nm | Aperture: 9.5 mm | Response Time (0-90%): 0.25 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 5% @200-400nm, ±3% @400-1000nm, ±5% @1000-1100nm | View family documentation |
| PD-50-D9-VIS | LaserPoint | Photodiodes | Max. Average Power (1): 50 mW | — | Calibration spectral range: 400 - 1100 nm | Aperture: 9.5 mm | Response Time (0-90%): 0.25 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 5% @400-500nm, ±3% @500-1000nm, ±5% @1000-1100nm | View family documentation |
| PD-500-D9-VIS | LaserPoint | Photodiodes | Max. Average Power (1): 500 mW | — | Calibration spectral range: 400 - 1100 nm | Aperture: 9.5 mm | Response Time (0-90%): 0.25 sec | Cooling: Convection | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 5% @400-500nm, ±3% @500-1000nm, ±5% @1000-1100nm | View family documentation |
| W-1500-D40-HPB | LaserPoint | Thermal Sensors | Max. Average Power: 1500 W | Max. Energy (with 100 ms pulse): 2250 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 40 mm | Response Time (0-90%): 4 sec | Cooling: Water (a) | Cable length - connector: 5.0 m - DB15 5.0 m – USB (U option) 5.0 m - RS232 (R option) | Power Calibration Uncertainty: ± 5% | View family documentation |
| W-1500-D40-SHC | LaserPoint | Thermal Sensors | Max. Average Power: 1500 W | Max. Energy (with 100 ms pulse): 2250 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 40 mm | Response Time (0-90%): 4 sec | Cooling: Water (a) | Cable length - connector: 5.0 m - DB15 5.0 m – USB (U option) 5.0 m - RS232 (R option) | Power Calibration Uncertainty: ± 5% | View family documentation |
| W-200-D40-HPB | LaserPoint | Thermal Sensors | Max. Average Power: 200 W | Max. Energy (with 100 ms pulse): 300 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 40 mm | Response Time (0-90%): 2 sec | Cooling: Water (a) | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| W-200-D40-SHC | LaserPoint | Thermal Sensors | Max. Average Power: 200 W | Max. Energy (with 100 ms pulse): 300 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 40 mm | Response Time (0-90%): 2 sec | Cooling: Water (a) | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| W-3000-D55-HPB | LaserPoint | Thermal Sensors | Max. Average Power: 3 kW | Max. Energy (with 100 ms pulse): n.a. | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 55 mm | Response Time (0-90%): 5 sec | Cooling: Water (a) | Cable length - connector: 5.0 m - DB15 5.0 m – USB (U option) 5.0 m - RS232 (R option) | Power Calibration Uncertainty: ± 5% | View family documentation |
| W-3000-D55-SHC | LaserPoint | Thermal Sensors | Max. Average Power: 3 kW | Max. Energy (with 100 ms pulse): n.a. | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 55 mm | Response Time (0-90%): 5 sec | Cooling: Water (a) | Cable length - connector: 5.0 m - DB15 5.0 m – USB (U option) 5.0 m - RS232 (R option) | Power Calibration Uncertainty: ± 5% | View family documentation |
| W-600-D30-HPB | LaserPoint | Thermal Sensors | Max. Average Power: 600 W | Max. Energy (with 100 ms pulse): 800 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 30 mm | Response Time (0-90%): 2 sec | Cooling: Water (a) | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| W-600-D30-SHC | LaserPoint | Thermal Sensors | Max. Average Power: 600 W | Max. Energy (with 100 ms pulse): 800 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 30 mm | Response Time (0-90%): 2 sec | Cooling: Water (a) | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| W-600-D70-HPB | LaserPoint | Thermal Sensors | Max. Average Power: 600 W | Max. Energy (with 100 ms pulse): 800 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 70 mm | Response Time (0-90%): 2 sec | Cooling: Water (a) | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| W-600-D70-SHC | LaserPoint | Thermal Sensors | Max. Average Power: 600 W | Max. Energy (with 100 ms pulse): 800 J | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 70 mm | Response Time (0-90%): 2 sec | Cooling: Water (a) | Cable length - connector: 1.5 m - DB15 2.5 m – USB (U option) 1.5 m - RS232 (R option) | Power Calibration Uncertainty: ± 3% | View family documentation |
| W-6000-D55-SHC | LaserPoint | Thermal Sensors | Max. Average Power: 6 kW | Max. Energy (with 100 ms pulse): n.a. | Absorber Spectral Range: 0.19 - 11 µm | Aperture: 55 mm | Response Time (0-90%): 3.5 sec | Cooling: Water (a) | Cable length - connector: 5.0 m - DB15 5.0 m – USB (U option) 5.0 m - RS232 (R option) | Power Calibration Uncertainty: ± 5% | View family documentation |
No matching products.
Looking for a specific brand or product?
Contact our technical team and we will help you find the most suitable solution for your application.
Address