MV-CU060-10GC V2.0

3072 × 2048 pixels; 19.1 fps @ 3072 × 2048 Bayer RG 8; Gigabit Ethernet (1000 Mbit/s), compatible with Fast Ethernet (100 Mbit/s); color.

SKU: HIK-MV-CU060-10GC V2.0 Category:
Contact us to inquire about this product

If you love this product and wish for a customized quote contact us at number +34 91 3854 395 and we will be happy to provide you with more info!

Product overview

MV-CU060-10GC V2.0 is a HIKROBOT industrial camera in the CU Series family. Its documented sensor resolution is 3072 × 2048 pixels, with a maximum frame rate of 19.1 fps @ 3072 × 2048 Bayer RG 8. Data interface: Gigabit Ethernet (1000 Mbit/s), compatible with Fast Ethernet (100 Mbit/s).

Documentation

HIKROBOT MV-CU060-10GM/GC V2 family datasheet

ManufacturerHIKROBOT
Resolution (original value)3072 × 2048
Frame rate and measurement conditions19.1 fps @ 3072 × 2048 Bayer RG 8
Shutter typeRolling shutter
Data interfaceGigabit Ethernet (1000 Mbit/s), compatible with Fast Ethernet (100 Mbit/s)
Color / MonoColor
Exposure range52 µs to 10 sec
Family documentationView family documentation
Sensor layoutArea scan
Detector technologyCMOS
Sensor modelSony® IMX178
Sensor format1/1.8"
Pixel pitch2.4 × 2.4 µm
Lens mountC-mount
Dimensions29 mm × 29 mm × 42 mm
Camera seriesCU Series
Video output formatsBayer RG 8/10/10Packed/12/12Packed
Dynamic range (manufacturer value)71.3 dB
Ingress protection and conditionsIP30 (under proper lens installation and wiring)
Supply voltage9 VDC to 24 VDC, PoE is optional
Power consumption and conditionsTyp. 1.7 W @ 12 VDC
Gain range0 dB to 24 dB
Operating temperature and measurement pointWorking temperature: 0 °C to 50 °C
Digital I/O and connectors6-pin P7 connector provides power and I/O, including opto-isolated input × 1 (Line 0), opto- isolated output × 1 (Line 1), bi-directional non-isolated I/O × 1 (Line 2).
Model configuration details
Sensor type CMOS, rolling shutter
Sensor model Sony® IMX178
Pixel size 2.4 µm × 2.4 µm
Sensor size 1/1.8"
Resolution 3072 × 2048
Max. frame rate 19.1 fps @ 3072 × 2048 Bayer RG 8
Dynamic range 71.3 dB
SNR 41.3 dB
Gain 0 dB to 24 dB
Exposure time 52 µs to 10 sec
Exposure mode Off/Once/Continuous exposure mode
Mono/color Color
Pixel format Bayer RG 8/10/10Packed/12/12Packed
Binning Supports 1 × 1, 2 × 2
Decimation Supports 1 × 1, 2 × 2, 4 × 4
Reverse image Supports horizontal and vertical reverse image output
Data interface Gigabit Ethernet (1000 Mbit/s), compatible with Fast Ethernet (100 Mbit/s)
Digital I/O 6-pin P7 connector provides power and I/O, including opto-isolated input × 1 (Line 0), opto- isolated output × 1 (Line 1), bi-directional non-isolated I/O × 1 (Line 2).
Power supply 9 VDC to 24 VDC, PoE is optional
Power consumption Typ. 1.7 W @ 12 VDC
Lens mount C-mount
Dimension 29 mm × 29 mm × 42 mm (1.1" × 1.1" × 1.7")
Weight Approx. 100 g (0.2 lb.)
Ingress protection IP30 (under proper lens installation and wiring)
Temperature Working temperature: 0 °C to 50 °C (32 °F to 122 °F) Storage temperature: –30 °C to 80 °C (–22 °F to 176 °F)
Humidity 20% RH to 95% RH (no condensation)
Client software MVS or third-party software meeting with GigE Vision Protocol
Operating system 32/64-bit Windows 7/10, 64-bit Windows 11, 32/64-bit Linux
Compatibility GigE Vision V2.0, GenlCam
Certification CE, RoHS, KC

Values and conditions describe this exact model or the applicable column in its family datasheet. Maximum rates depend on the documented acquisition, output format, lighting and operating configuration. The image is the manufacturer’s representative photograph extracted from the verified document; it may show another documented lens or mounting option within the family. Optional lenses, illumination, cables and accessories are not implied to be included.

The linked PDF is an original HIKROBOT manufacturer document recovered from a distributor. Its revision is retained as supplied; confirm the required hardware revision, software compatibility and availability with IberOptics. No stock availability is asserted.

I have read and accepted your terms and conditions and privacy policy