MV-CI003-GL-T6

HIKROBOT HIK-MV-CI003-GL-T6. 640 × 512 pixels. 50 fps at 640 × 512. GigE (1 Gb/s; compatible with 100 Mb/s Fast Ethernet).

SKU: HIK-MV-CI003-GL-T6 Category:
Contact us to inquire about this product

If you love this product and wish for a customized quote contact us at number +34 91 3854 395 and we will be happy to provide you with more info!

Product overview

MV-CI003-GL-T6 is a HIKROBOT industrial LWIR camera with an uncooled vanadium oxide detector. It records 640 × 512 thermal images at up to 50 fps, with 17 µm detector pixels and a 6.3 mm lens. Its field of view is 88.5° × 73.2°.

Gigabit Ethernet provides the digital interface, with Fast Ethernet compatibility and GigE Vision 2.0 / GenICam support. Camera dimensions are 48 × 48 × 117.9 mm. NETD is < 50 mK (F/1.0, 30 °C); the stated test conditions are part of the specification.

This radiometric variant supports temperature measurements using points, lines, polygons and circles, plus region-based alarms. Selectable measurement ranges are –20 °C to 150 °C and 0 °C to 550 °C. Stated accuracy is ±2 °C or ±2% of the reading. Its detector is uncooled; the T6 designation does not establish TEC cooling.

The linked family datasheet covers this exact model. The photograph supplied by the distributor shows the family housing; fitted optics vary by model.

Documentation

MV-CI003-GL-Tx family datasheet

ManufacturerHIKROBOT
Resolution (original value)640 × 512 pixels
Frame rate and measurement conditions50 fps at 640 × 512
CoolingUncooled
Data interfaceGigE (1 Gb/s; compatible with 100 Mb/s Fast Ethernet)
Color / MonoMonochrome thermal image; selectable false-color palettes
Family documentationView family documentation
Sensor layoutArea sensor
Detector technologyVanadium oxide microbolometer
Pixel pitch17 µm
Dimensions48 × 48 × 117.9 mm
Focal length6.3 mm
Field of view88.5° × 73.2°
NETD and measurement conditions< 50 mK (F/1.0, 30 °C)
Thermal functionRadiometric temperature measurement
Temperature measurement range–20 °C to 150 °C or 0 °C to 550 °C
Temperature accuracy±2 °C or ±2% of the reading