BM-A-5W-14-TX

1 mW–5 W, continuous average power; 1–40 µJ at 1064 nm, pulse duration <10 ns; 40–1000 µJ at 1064 nm, pulse duration 10 ms

SKU: LPT-BM-A-5W-14-TX Category:
Contact us to inquire about this product

If you love this product and wish for a customized quote contact us at number +34 91 3854 395 and we will be happy to provide you with more info!

Product overview

BM-A-5W-14-TX is a high-sensitivity BLINK thermal laser measurement reference. Pulse-energy limits depend on wavelength and pulse duration; the continuous power limit is separate from the brief overload rating. Select the compatible high-speed meter separately.

Documentation

LaserPoint high-speed thermal sensors family catalogue — 2024 revision 1

ManufacturerLaserPoint
CoolingConvection; recommended ambient 10–30 °C
Spectral range and conditions0.2–11 µm absorber range; calibration wavelengths selected separately
Data interfaceHirose IX sensor connection to HSM-1000
Family documentationView family documentation
Dimensions60x60x16.5 mm
Product typeHigh-speed thermal power/energy sensor
Measured power and conditions1 mW–5 W, continuous average power
Measured energy and conditions1–40 µJ at 1064 nm, pulse duration <10 ns; 40–1000 µJ at 1064 nm, pulse duration 10 ms
Active aperture14 × 14 mm; minimum beam diameter 3 mm
Measurement uncertainty±5% power / ±5% energy calibration uncertainty
Repetition rate and conditionsUp to 1 MHz, within documented pulse-energy and average-power limits
Model configuration details
Max. Average Power 5 W
Max. Average Power (1) 15 W
Power Calibration Uncertainty ± 5%
Max repetition rate 1 MHz
Energy Resolution 0.01 µJ
Energy Calibration Uncertainty ± 5%
Aperture 14 x 14 mm
Type T
Spatial Uniformity (2) ± 5 %
Min. Beam diameter 3 mm
Absorber Spectral Range 0.2 - 11 µm
Calibration Spectral Range 0.355 µm 0.532 µm 1.07 µm 10.6 µm (c) (d)
Max Power Density (3) 0.1 kW/cm²
Max Energy Density (4) 35 mJ/cm²
Cooling Passive (e)
Maximum sensor operating temperature 60 °C
Dimensions 60x60x16.5 mm
Cable length 2 m
Stand and Post Light Duty Stand
(1) max 2 sec exposure, max 20% duty cycle. (2) 3mm beam diameter, scanning 80% of active area (3) Damage thresholds also depend on power level. (4) Single shot (a). wavelength 1064nm, pulse duration < 10 ns (b). wavelength 1064nm, pulse duration = 10 ms (c). 10.6 µm sensor reflectivity 70% (d). Others wavelength on request (e). Recommended ambient temperature: 10 -30 °C
Pulse energy and measurement conditions 1–40 µJ at 1064 nm, pulse duration <10 ns; 40–1000 µJ at 1064 nm, pulse duration 10 ms
Calibration and absorber Absorber range is not the calibration range. Standard listed calibrations: 355, 532 and 1070 nm; 10.6 µm option has 70% reflectivity; other wavelengths on request.
Cooling and conditions Convection; recommended ambient 10–30 °C
Meter configuration Compatible HSM-1000 meter is selected separately
Maximum transient average power 15 W for at most 2 s and at most 20% duty cycle