| Product type |
Dual laser current and temperature controller family |
| Current Channels per Unit |
DLC-200 Value: 2; DLC-500 Value: 2 |
| Current Capacity per Channel |
DLC-200 Value: 200; DLC-500 Value: 500; Units: mA |
| Minimum Deliverable Current |
DLC-200 Value: 0; DLC-500 Value: 0; Units: mA |
| Polarity |
DLC-200 Value: Cathode ground only; DLC-500 Value: Cathode ground only |
| Current Noise Density |
DLC-200 Value: ≤100; DLC-500 Value: ≤200; Units: pA/√Hz; Comments: At > 1 kHz |
| Current Noise |
DLC-200 Value: ≤50 ≤100 ≤300; DLC-500 Value: ≤100 ≤150 ≤500; Units: nA, rms; Comments: Integrated from 10 Hz to 100 kHz Integrated from 10 Hz to 1 MHz Integrated from 10 Hz to 10 MHz |
| Current Setpoint Resolution |
DLC-200 Value: ≤0.0002; DLC-500 Value: ≤0.0005; Units: mA |
| Temperature Drift |
DLC-200 Value: ≤1; DLC-500 Value: ≤1; Units: µA/°C |
| Compliance Voltage |
Value: ≤18; Units: V; Comments: automatically adjusted |
| Servo Input Bandwidth |
DLC-200 Value: ≥10; DLC-500 Value: ≥10; Units: MHz |
| RF Input Modulation Bandwidth |
DLC-200 Value: 1; DLC-500 Value: 1; Units: GHz |
| LIV Acquisition Range |
DLC-200 Value: 0 to Imax; DLC-500 Value: 0 to Imax; Units: mA |
| LIV Acquisition Time |
DLC-200 Value: 1 to 100; DLC-500 Value: 1 to 100; Units: s |
| Total Temp. Channels |
Value: 4; Comments: 2 per current channel |
| Compatible Transducer |
Value: TEC or resistive heater |
| Compatible Sensor |
Value: NTC thermistor |
| Temperature Stability |
Value: ±0.2; Units: mK; Comments: w/ properly designed temperature plant |
| Precision |
Value: ±0.2; Units: mK |
| Control Capacity |
Value: 20; 40; Units: W; Comments: per channel; total |
| Current Capacity |
Value: 5; Units: A; Comments: per temperature plant |
| Input Impedance |
Value: 50, 1M; Units: Ω; Comments: Configurable |
| Input Voltage Limit |
Value: ±10; Units: V |
| Output Voltage Range |
Value: ±10; Units: V |
| Overvoltage Category |
Value: 2 |
| Input Line Voltage |
Value: 100 - 240; Units: VAC |
| Mains Supply Voltage Fluctuations |
Value: ±10; Units: % |
| Frequency |
Value: 50 - 60; Units: Hz |
| Phase |
Value: 1 phase |
| Maximum Input Current |
Value: 2; Units: A |
| User-Serviceable Fuse |
Value: HBC 2.0 A 250 V |
| Indoor or Outdoor Use |
Min. Value: Indoor Use Only; Comments: Dry Location Only |
| Pollution Degree of Environment |
Max. Value: 2 |
| Operating Altitude |
Max. Value: 10000 (3048); Units: ft (m) |
| Operating Temperature |
Min. Value: 15; Max. Value: 30; Units: °C |
| Operating Relative Humidity |
Min. Value: 20; Max. Value: 60; Units: %; Comments: Non-condensing |
| Dew Point |
Max. Value: 15; Units: °C |
| Controller channels |
2 current channels; 4 temperature channels |
| Output current |
200 or 500 mA maximum per current channel, configuration dependent |